La familia de conversores consta de 5 equipos principales. Cada equipo tiene diferentes opciones de encapsulado en función de los conectores disponibles
rder Code | Description | Operating Temperature | |
Series CAN from/to Modbus RTU |
|||
HD67011 | CAN / Modbus Master - Converter ( Housing type: A, Terminal Blocks Connectors ) |
-30° to +70° | |
HD67012 | CAN / Modbus Slave - Converter ( Housing type: A, Terminal Blocks Connectors ) |
-30° to +70° | |
Series CAN from/to Modbus Master |
|||
HD67411-E4V | CAN / Modbus Master - Converter ( Housing type: E, Mini-Fit Connectors, Triple Galvanic Isolation: 4KV, PCB Treatment: Varnished ) |
-40° to +105° | |
HD67411-E7V | CAN / Modbus Master - Converter ( Housing type: E, SuperSeal 1.5 Connectors, Triple Galvanic Isolation: 4KV, PCB Treatment: Varnished ) |
-40° to +105° | |
HD67411-E4R | CAN / Modbus Master - Converter ( Housing type: E, Mini-Fit Connectors, Triple Galvanic Isolation: 4KV, PCB Treatment: Resibed ) |
-40° to +105° | |
HD67411-E7R | CAN / Modbus Master - Converter ( Housing type: E, SuperSeal 1.5 Connectors, Triple Galvanic Isolation: 4KV, PCB Treatment: Resined ) |
-40° to +105° | |
Series CAN from/to Modbus Slave |
|||
HD67412-E4V | CAN / Modbus Slave - Converter ( Housing type: E, Mini-Fit Connectors, Triple Galvanic Isolation: 4KV, PCB Treatment: Varnished ) |
-40° to +105° | |
HD67412-E7V | CAN / Modbus Slave - Converter ( Housing type: E, SuperSeal 1.5 Connectors, Triple Galvanic Isolation: 4KV, PCB Treatment: Varnished ) |
-40° to +105° | |
HD67412-E4R | CAN / Modbus Slave - Converter ( Housing type: E, Mini-Fit Connectors, Triple Galvanic Isolation: 4KV, PCB Treatment: Resined ) |
-40° to +105° | |
HD67412-E7R | CAN / Modbus Slave - Converter ( Housing type: E, SuperSeal 1.5 Connectors, Triple Galvanic Isolation: 4KV, PCB Treatment: Resined ) |
-40° to +105° | |
Series CAN from/to Modbus TCP Master |
|||
HD67514-A1 | CAN / Modbus TCP Master - Converter ( Housing type: A, Terminal Blocks Connectors ) |
-30° to +70° | |
HD67514-B2 | CAN / Modbus TCP Master - Converter ( Housing type: B, Terminal Blocks Connectors ) |
-30° to +70° | |
Series CAN from/to Modbus TCP Slave |
|||
HD67515-A1 | CAN / Modbus TCP Slave - Converter ( Housing type: A, Terminal Blocks Connectors ) |
-30° to +70° | |
HD67515-B2 | CAN / Modbus TCP Slave - Converter ( Housing type: B, Terminal Blocks Connectors ) |
-30° to +70° |
El Gateway CAN a / desde Modbus es un dispositivo electrónico que permite el intercambio de información entre un bus CAN y un Modbus RTU / ASCII / JBUS sobre RS232/RS485, o entre un bus CAN y bus Modbus TCP (a través de Ethernet).
Por todos los Modbus existe la posibilidad para el gateway de ser maestro o esclavo para las versiones RTU / ASCII / JBUS y cliente o servidor para las versiones TCP.
Los gateways HD67514 y HD67514-B2 son clientes (es decir, Maestro) desde el lado de TCP, por lo que permite la comunicación entre los dispositivos CAN y los servidores Modbus TCP (p.ej, esclavos) y viceversa. .
Los gateways HD67515 y HD67515-B2 son servidores (es decir, Esclavo) desde el lado de TCP, por lo que permite la conexión entre dispositivos CAN y clientes Modbus TCP (p.ej, maestros), y viceversa. .
El gateway HD67011 es Maestro desde el lado RTU / ASCII / JBUS, lo que permite la comunicación entre dispositivos CAN y esclavos Modbus y viceversa.
El gateway HD67012 es esclavo desde el lado RTU / ASCII / JBUS, por lo que permite la comunicación entre los dispositivos CAN y maestro Modbus y viceversa.